Project

General

Profile

Actions

Feature #12066

closed

handle dark subtraction and gain correction separately

Added by Anchi Cheng about 2 years ago. Updated over 1 year ago.

Status:
Closed
Priority:
Normal
Assignee:
-
Category:
-
Target version:
Start date:
02/16/2022
Due date:
% Done:

0%

Estimated time:
Deliverable:

Description

There are too many different cases. For example, K3 is collected with camera handling dark subtraction, Falcon4EC with EER collected with the returned sun both dark and gain corrected, but we need to save norm image in the metadata for post processing of the EER file.

Actions #1

Updated by Anchi Cheng about 2 years ago

Removed "system corrected"
Added
"system dark subtracted": for electron counting camera
"frame gain corrected": for example, Falcon series with mrc frames, de20
"sum gain corrected": usually the same as frame gain corrected except Falcon4EC operated in EER mode.

Actions #2

Updated by Anchi Cheng over 1 year ago

  • Status changed from Assigned to Closed

works

Actions

Also available in: Atom PDF