Project

General

Profile

Continuous tilt electron diffraction recording » History » Version 37

Anchi Cheng, 07/27/2022 11:55 AM

1 6 Anchi Cheng
h1. Continuous tilt electron diffraction recording use Ceta or Ceta-D camera and TFS scopes
2 1 Anchi Cheng
3 37 Anchi Cheng
Micro-ED involves recording 3D crystal electron diffraction pattern during a continuous stage tilt.  Leginon implementation of this application includes the listed components below and is available by using myami-beta branch and myami-3.5 and above.  As is, it is only fully implemented for TFS Ceta or Ceta-D camera.
4 1 Anchi Cheng
5
Since many of the feature required here are not available through Standard or Advanced TEM Scripting from TFS, AutoIt scripts are used in several places.
6
7
h2. Components of the feature
8
9 5 Anchi Cheng
# Diffraction mode TEM instrument
10 8 Anchi Cheng
# Beamstop control: achieved by AutoIt Scripts BeamstopIn and BeamstopOut
11 9 Anchi Cheng
# Rolling-shutter movie acquisition using TIA interface
12 23 Anchi Cheng
# [[TIA raw data conversion|Data conversion]] and upload of the movies into Leginon database and crystallography format
13 4 Anchi Cheng
# [[ MSI-Diffr application ]]
14 11 Anchi Cheng
# [[Camera length calibration]]
15 1 Anchi Cheng
16
h2. Installation (assuming that you've already have Leginon installation).
17
18
# Check that you have access to Advanced TEM Scripting (frame-saving upgrade not needed).
19 28 Anchi Cheng
# Install or set environment to use git branch myami-3.5 and up or the current myami-beta on TFS microscope with Ceta camera as well as your leginon linux box and webserver for myamiweb.
20 10 Anchi Cheng
# import updated Calibrations application (see [[Steps_involved_in_the_installation]])
21
# import MSI-diffraction  and settings from your_myami/leginon/applications (see general description of [[Steps_involved_in_the_installation]] regarding importing application and additional settings for the application)
22 5 Anchi Cheng
# [[Setup Diffraction mode TEM instrument]]
23 7 Anchi Cheng
# [[Setup Ceta to use Advanced TEM Scripting]]
24 3 Anchi Cheng
# [[AutoIt program and script compilation]]
25 20 Anchi Cheng
# [[Setup movie upload with diffrtransfer.py]]
26 21 Anchi Cheng
27 32 Anchi Cheng
* On scopes that has both Falcon and Ceta, and the former is used for typical imaging, we create instruction for diffraction users to replace instruments.cfg with the one specific for diffraction work during their operation and then have them change it back afterward.
28
29 27 Anchi Cheng
h2. Microscope optical settings
30 1 Anchi Cheng
31 27 Anchi Cheng
* Gun Lens: 7.1 is the typical we use.  This delievers about 1/4 of the beam intensity of Gun Lens 3.3 on Glacios
32 36 Anchi Cheng
** We do not retake Gain reference at such high Gun Lens value.  The beam is weak in imaging mode in this case and does not give the right gain reference for the diffraction peaks.
33 27 Anchi Cheng
* C2 Aperture: 20 um for any SA and diffraction presets. 150 um, or what you typically use that does not block the beam for grid atlas
34
* Probe mode: nano probe parallel illumination whereever possible
35
36
h2. Presets unique for this application (Glacios with CetaD and 0.9 Å resolution)
37
38
|preset name|TEM|magnification(camera length)|SpotSize|Parallel?|Notes|
39
|hl|Glacios|8500|10|No|Minimize exposure dose is important since this preset is used for all target tracking and eucentric height adjustment|
40
|df|DiffrGlacios|1100|10|Yes|Exposure time is only relevant for Diffraction node where single acquistion is taken|
41
42 26 Anchi Cheng
h2. Calibration
43 27 Anchi Cheng
44 1 Anchi Cheng
# [[Camera length calibration]]
45
46
h2. Usage
47 2 Anchi Cheng
48
h3.  Check these before you start:
49 15 Anchi Cheng
50 31 Anchi Cheng
# Confirm that instruments.cfg is properly set up to use feicam for Ceta camera.  *Falcon camera and Ceta camera can not both be loaded through feicam in instruments.cfg*
51 29 Anchi Cheng
# Set gun lens value.  This must be done manually.  Use "Free control" option if needed.
52 27 Anchi Cheng
# Open TUI. Select and insert BM-Ceta in the camera tab. Confirm that tui_acquire.au3 validation items are set [[Autoit program and script compilation#TUIAcquire-Testing|correctly]]. 
53
# Make sure TIA window is available and the Export Series shortcut is shown as required by [[Autoit program and script compilation#TiaExportSeries-Testing|TiaExportSeries.au3]]
54 15 Anchi Cheng
55 13 Anchi Cheng
h3. Start MSI-DIffr application and assign client as required.
56
57 1 Anchi Cheng
h3. [[Setup df preset]]
58 15 Anchi Cheng
59
h3. Grid atlas collection
60
61
1. Select gr preset to scope, with flucam showing the grid and aperture, draw on the computer screen the location of the centerred small C2 aperture.
62
2. Select a larger C2 aperture for grid atlas collection.
63
3. collect grid atlas.
64
4. Reselect the small C2 aperture.  Make sure it is still centered.
65
66
h3. Queue up potential crystals
67
68
1. Pick square and then pick "hole" for intermediate mag image of potential crystals.  (This is no different from any other MSI application).
69
2. Submit preview targets in "DExposure Targeting" node for a small rotation image and confirm whether it diffracts or not.
70
3. Submit the good crystal positions as acquisition targets into the queue in "DExposure Targeting" node.  No focus target is needed.
71
4. If needed, modify "DExposure" settings for start, range, and speed of the tilt.
72
5. Click "process queue" tool to start collection
73 24 Anchi Cheng
74 35 Anchi Cheng
h4. Important: Do not use "simulate target" tool directly in "DExposure" node.  It needs a real target id to keep the tilt series saved unique and for diffrtransfer.py to function.
75 33 Anchi Cheng
76 24 Anchi Cheng
h3. Diffraction series naming convension
77
78
The diffraction series is named after the parent image database id and target number in its target list.  For example, 123456_1