RUNNING THE PROGRAM:
----------------------

To run the program, type:

./ApTiltPicker.py -1 image1.mrc -2 image2.mrc -p tiltpicks.spi

'tiltpicks.spi' is optional. I left an example in the tiltpicker folder. You must run the program in the tiltpicker folder. To run the example type:

./runPicker.sh

If all works the picker will open up and you'll have two images of ribosomes.

BUG TRACKING:
----------------------

TiltPicker bugs are now tracked via the AMI redmine server, visit
http://emg.nysbc.org/projects/tiltpicker/
to file any bugs

YOUTUBE MOVIE:
----------------------

I just made a screen capture video on how to use it. It is available is low resolution on youtube:

http://www.youtube.com/watch?v=cw1osPBY_JM

or you can download the full screen version from the appion.org website:

http://code.google.com/p/appion/downloads/list

I recommend using VLC to watch it:

http://www.videolan.org/vlc/

STEP BY STEP TUTORIAL:
----------------------

  • Start TiltPicker
    • Extract TiltPicker, on command line type:

      tar -zxf tiltpicker-2.0.tgz

    • Go to tiltpicker directory, on command line type:

      cd tiltpicker

  • Display TiltPicker help, on command line type:
    ./ApTiltPicker.py -h
  • Open TiltPicker, on command line type:

    ./ApTiltPicker.py -l data/rawu048b.jpg -r data/rawu049b.jpg -t 50.0

  • Initialize alignment:
    • Maximize window
    • Set correct zoom for images
    • Center the middle bar
    • Pick 5 partcle pairs
    • Save picks to a file
    • Hit the apply button, circles will not match crosses
    • Find theta (tilt angle)
    • Optimize inplane rotations
    • Optimize all parameters
    • Mask region to only look at overlapping regions, overlap is shown on status bar
    • Hit Auto optimize, it performs find theta, optimize angles and mask in a single click
    • If you look at the Terminal it will tell you how many optimization rounds were performed
    • Use transfer picks button, this works but is based on the alignment parameters
  • Auto pick particles
    • Measure particle size using ruler tool, zoom in to get best value
    • Run DoG picker with wrong contrast
    • Reject picks
    • Run DoG picker with correct contrast
    • Show terminal
    • Accept picks
    • Look at DoG map images
  • Clean up particle picks
    • Use clear bad picks button
    • Use polygon tool
    • Auto optimize
    • Use cutoff button to remove picks below a threshold
    • Add more picks
    • Save and quit