Gatan on Windows with semccddll » History » Revision 8
Revision 7 (Anchi Cheng, 02/02/2016 02:44 PM) → Revision 8/11 (Anchi Cheng, 02/02/2016 03:23 PM)
h1. Gatan on Windows-32 with SEMCCD.dll dmsem module uses SEMCCD.dll written for SerialEM to communicate with Gatan software rather than tecnaiccd.dll If using this on a computer different from the scope computer, please read [[Using_Leginon_on_a_system_where_the_microscope_and_camera_are_controlled_by_different_computers|this]] first. h2. Extra Package and Installation * Use all win32 version of Windows installer * SerialEM DigitalMicrograph Plug-in {{include(Install_SerialEM_DigitalMicrograph_plugin)}} h2. instruments.cfg Currently UltraScan and Orius camera are supported. For UltraScan camera (US4000), set instruments.cfg to use GatanUltraScan class. For example: <pre> [us4000] class: dmsem.GatanUltraScan zplane: 50 height: 4096 width: 4096 </pre> For Orius camera, set instruments.cfg to use GatanOrius class. h2. Setup {{include(dm camera configuration)}} h2. (Version 3.2) Define local configuration in dmsem.cfg # Copy from your myami checkout pyscope/dmsem.cfg.template to C:\Program Files\myami\dmsem.cfg # Make changes to the configured value in dmsem.cfg Most parameters are explained above. * *The config parser takes "'" and "\" literally*. Therefore, do not include "'" in DM_VERION. In addition, the path separator should be "\" * *CAMERA_ID* is usually 0 if it is the only Gatan camera. * *Ultrascan camera should be configured under utrascan module, and Orius camera should be configured under orius module. For example, only UltraScan camera exists on this computer that has Digital Micrograph version 2.32.788.0, and DM camera configuration has vertical flip but no rotation, then set the dmsem.cfg ultrascan module like this: <pre> [dm] DM_VERSION = 2.32.788.0 [ultrascan] CAMERA_ID = 0 FLIP = True ROTATE = 0 </pre> h2. Testing with pyscope {{include(Gatan_UltraScan_dmsem_Installation_Pyscope_Test)}} h2. Trouble shooting h3. Refused socket connection {{includ(trouble shooting semccd If an error of "No connection could be made because the target machine actively refused it" comes up in the above test. If not blocked by firewall, the SERIALEM_CCD_PORT specified in environment variable may be locked by a remaining previous attempt. You can check active tcp port with Windows command <pre> netstat </pre> * In some case, you will find SERIALEMCCD or similar listed in Windows Task Manager Processing list. If so, and that process remains after Digital Micrograph is closed, you can terminate it from Task Manager. * CurrPorts is a program that can be used to check and close socket connection)}} tcp connection with gui. h3. SerialEM-CCD plugin can output the command it issues and results to DM's result panel if you set the environment variable SERIALEMCCD_DEBUG to larger than 0. Set to 1 to show general log. Set to 2 to also include socket communication log. Please activate this debug log and include the portion that shows problem when reporting problems to Leginon team. h2. Programs to open before Leginon Client: Digital Micrograph