Project

General

Profile

Initial MSI application preference setup » History » Version 16

Anchi Cheng, 12/21/2010 09:53 PM

1 1 Amber Herold
h1. Initial MSI application preference setup
2
3
Many of the preferences are matched to the function of the nodes and therefore are more like configuration. Starting from v1.5, the "Administrator" default preferences are loaded during the installation ready for standard MSI operation assuming the use of example preset names and properties. This means that as a new user, you don't have t
4
5
The following is the comprehensive list of what is set as default during the initial loading. In some cases, the reason behind the setting is also included. Each institution can alter these default values according to their particular need for all their new users.
6
7 5 Eric Hou
Table 16.1 Example MSI node setup
8
9 16 Anchi Cheng
|_.Node name:|_.preset:|_.move type (to reach the preset) :|_.wait for a node to process the image:|_.publish and wait for rejected targets:|_.adjust target using ancestor:|
10 1 Amber Herold
|Grid Targeting|gr|N/A|N/A|N/A|N/A|
11
|Grid|gr|modeled stage position|no|no|no|
12
|Square|sq|modeled stage position|yes|no|no|
13 16 Anchi Cheng
|Hole|hl|modeled stage postion|yes|yes|one|
14
|Z Focus|hl or fc*|modeled stage position|no|no|one|
15
|Exposure|en & ef|image shift|no|yes|one|
16
|Focus|fc|image shift|no|no|one|
17 1 Amber Herold
18 9 Eric Hou
* *Use hl if your z focus target will be at the center of a hole where its fft image don't have obvious Thone rings. Use fc if the target is on carbon film for better accuracy.
19 6 Eric Hou
 
20
Leave other setting options to default. These default options are:
21
 
22 9 Eric Hou
##  Wait 2.5 seconds before acquiring image
23 6 Eric Hou
 
24 9 Eric Hou
##  Save image to database = yes
25 6 Eric Hou
 
26
Remember to press the "+" button in order to assign a preset to a node._
27
 
28 9 Eric Hou
*  Presets Manager/Settings>
29 6 Eric Hou
 
30 1 Amber Herold
paus time between preset changes = 1 sec.
31 6 Eric Hou
 
32 1 Amber Herold
Cycle presets = yes
33 6 Eric Hou
 
34 1 Amber Herold
Optimize preset cycle = yes
35 6 Eric Hou
 
36 1 Amber Herold
Cycle Magnification Only = yes
37 6 Eric Hou
 
38 1 Amber Herold
The cycle order should match the sequence of data acquisition to minimize hysterisis. If the presets are imported from previous session, the cycle order is imported automatically. As an example, the cycle for naming scheme used here at NRAMM is gr -> sq -> hl -> fa -> fc -> en -> ef.
39 6 Eric Hou
 
40 9 Eric Hou
*  Grid Targeting/Settings>
41 7 Eric Hou
 
42 9 Eric Hou
#  Select Preset = gr
43 1 Amber Herold
 
44 9 Eric Hou
#  Label =
45 1 Amber Herold
 
46
*Enter a new label for each new atlas that is acquired for this session. The first atlas requires no label. This label will be included in the image file name; therefore, shorter names are preferred.
47
 
48 9 Eric Hou
#  Radius = 0.0009 m covers about the whole grid.
49 1 Amber Herold
 
50 9 Eric Hou
#  Mosaic center = stage center
51
52
*  Square Targeting/Settings> Ignore all settings. No need to set these general targeting finding configuration
53
54
*  Square Targeting/Mosaic Settings>
55 1 Amber Herold
 
56 9 Eric Hou
##  Calibration Parameter = stage model position
57 1 Amber Herold
 
58 9 Eric Hou
##  Scale Image = yes (default)
59 1 Amber Herold
 
60 9 Eric Hou
##  Scale Image pixel size = 512 (or the size of the grid image that will be used to build the atlas). A larger value can be used in future loading of the tile list.
61
62
*  Hole Targeting/Settings and Exposure Targeting/Settings>
63 1 Amber Herold
 
64 9 Eric Hou
##  Allow for user verification of picked holes = yes
65 1 Amber Herold
 
66 9 Eric Hou
##  Queue up targets= no
67 1 Amber Herold
 
68 9 Eric Hou
##  Declare drift when queue is submitted = yes (default)
69 1 Amber Herold
 
70 9 Eric Hou
##  Skip auto picking of holes = yes (change to No after proper setup of the hole-finding algorithm)
71
72
*  Focus/Settings> and Z Focus/Settings>
73 8 Eric Hou
 
74 9 Eric Hou
##  Acuire post-focus image = yes
75 1 Amber Herold
 
76 9 Eric Hou
##  Melt time = 0 second (should be customized for each grid)
77
78 11 Eric Hou
Table 16.2 Example MSI Focus Setup
79 1 Amber Herold
80
|_.Step:|_.preset:|_.focus method:|_.correction type:|_.Enabled:|
81
|Z_to_Eucentric|fa|Beam Tilt|Stage Z|No|
82
|Def_to_Eucentric|fa|Beam Tilt|Defocus|Yes|
83
|Manual_after|fc|Manual|N/A|Yes| 
84
85 13 Eric Hou
*  Focus/Focus Sequence>
86
 
87
Enter 3 focus steps in the sequence list box by typing the name in the entry box and press "+" on its right.
88
 
89
Select individual step in the list box and set the following parameters
90
 
91 8 Eric Hou
For both autofocus steps:
92 1 Amber Herold
 
93 9 Eric Hou
##  Tilt = 0.01 radian each direction
94 8 Eric Hou
 
95 9 Eric Hou
##  Image registration = phase correlation
96 8 Eric Hou
 
97 9 Eric Hou
##  Fit limit = 1000
98 8 Eric Hou
 
99 9 Eric Hou
##  Correct for delta Defocus/Z between 0 and 2e-5 meters
100 8 Eric Hou
 
101 9 Eric Hou
##  Check drift greater than 3e-10 meters/s (should be customized by the user based on the exposure time and required resolution).
102 8 Eric Hou
 
103 1 Amber Herold
##  Stigmator correction = No (typical) Yes (if well calibrated)
104
 
105
##  Stigmator Defocus Min = 2e-06 meters
106
 
107
##  Stigmator Defocus Max = 4e-06 meters
108
109
Table 16.3 Example MSI Z Focus Steps.
110
111
|_.Step:|_.preset:|_.focus method:|_.Enabled:|
112
|Stage_Wobble|sq|Stage Tilt|No|
113
|Z_to_Eucentric|hl|Beam Tilt|Yes|
114
|Manual_after|fc or hl*|Manual|Yes|
115 11 Eric Hou
116 13 Eric Hou
* Z Focus/Focus Sequence>
117
 
118
The setup here works well for holey carbon grids. Continuous carbon with negative stain may require a different Z Focus Sequence because its low contrast at intermediate mag. See the Chapter on <link linkend="MSI-R_auto_focus">MSI-Raster application regarding improving autofocus</link>.
119
&nbsp;
120
Enter 2 focus step in the sequence list box by typing the name in the entry box and press "+" on its right.
121
&nbsp;
122
Select individual step in the list box and set the following parameters
123
&nbsp;
124 1 Amber Herold
*Use hl if your z focus target will be at the center of a hole where its fft image don't have obvious Thone rings. Use fc if the target is on the carbon film for better accuracy.
125 15 Eric Hou
126
**   For "Stage_Wobble" Step:
127 13 Eric Hou
&nbsp;
128
##  Tilt = 2 degrees each direction
129
&nbsp;
130
##  Image registration= phase correlation
131
&nbsp;
132
##  Fit limit = N/A
133
&nbsp;
134
##  Correct for delta Defocus/Z between 0 and 0.0002 meters
135
&nbsp;
136
##  Correction type = Stage Z
137
&nbsp;
138
##  Check drift greater than 3e-10 meters/s = No
139
&nbsp;
140
##  Stigmator correction = No
141 1 Amber Herold
&nbsp;
142
##  Stigmator Defocus Max/Min = N/A
143 15 Eric Hou
144
**   For "Z_to_Eucentric" Step:
145 14 Eric Hou
&nbsp;
146 13 Eric Hou
##  Tilt = 0.01 radian each direction
147
&nbsp;
148
##  Image registration= phase correlation
149
&nbsp;
150
##  Fit limit = 1500
151
&nbsp;
152
##  Correct for delta Defocus/Z between 0 and 0.0002 meters
153
&nbsp;
154
##  Correction type = Stage Z
155
&nbsp;
156
##  Reset defocus = Default
157
&nbsp;
158
##  Check drift greater than 3e-10 meters/s = No
159
&nbsp;
160
##  Stigmator correction = No
161
&nbsp;
162
##  Stigmator Defocus Max/Min = N/A
163 2 Amber Herold
164
165
______
166
167
[[MSI-Tomography Preferences|MSI-Tomography Preferences >]]
168
169 1 Amber Herold
______