Project

General

Profile

Initial MSI application preference setup » History » Version 5

Eric Hou, 06/24/2010 03:14 PM

1 1 Amber Herold
h1. Initial MSI application preference setup
2
3
Many of the preferences are matched to the function of the nodes and therefore are more like configuration. Starting from v1.5, the "Administrator" default preferences are loaded during the installation ready for standard MSI operation assuming the use of example preset names and properties. This means that as a new user, you don't have t
4
5
The following is the comprehensive list of what is set as default during the initial loading. In some cases, the reason behind the setting is also included. Each institution can alter these default values according to their particular need for all their new users.
6
7 5 Eric Hou
Table 16.1 Example MSI node setup
8
9 1 Amber Herold
|_.Node name:|_.preset:|_.move type (to reach the preset) :|_.wait for a node to process the image:|_.publish and wait for rejected targets:|_.adjust target for shift:|
10
|Grid Targeting|gr|N/A|N/A|N/A|N/A|
11
|Grid|gr|modeled stage position|no|no|no|
12
|Square|sq|modeled stage position|yes|no|no|
13
|Hole|hl|modeled stage postion|yes|yes|yes|
14
|Z Focus|hl or fc*|modeled stage position|no|no|yes|
15
|Exposure|en & ef|image shift|no|yes|yes|
16
|Focus|fc|image shift|no|no|yes|
17
18 5 Eric Hou
# *Use hl if your z focus target will be at the center of a hole where its fft image don't have obvious Thone rings. Use fc if the target is on carbon film for better accuracy.
19 1 Amber Herold
20 5 Eric Hou
** Leave other setting options to default. These default options are:
21 1 Amber Herold
22 5 Eric Hou
**  Wait 2.5 seconds before acquiring image
23 1 Amber Herold
24
25
*  Save image to database = yes
26
27
28
29
30
31
_Remember to press the "+" button in order to assign a preset to a node._
32
33
34
35
36
37
*  Presets Manager/Settings>
38
39
40
paus time between preset changes = 1 sec.
41
42
Cycle presets = yes
43
44
Optimize preset cycle = yes
45
46
Cycle Magnification Only = yes
47
48
49
The cycle order should match the sequence of data acquisition to minimize hysterisis. If the presets are imported from previous session, the cycle order is imported automatically. As an example, the cycle for naming scheme used here at NRAMM is gr -> sq -> hl -> fa -> fc -> en -> ef.
50
51
52
*  Grid Targeting/Settings>
53
54
55
56
57
58
*  Select Preset = gr
59
60
61
*  Label =
62
63
64
*Enter a new label for each new atlas that is acquired for this session. The first atlas requires no label. This label will be included in the image file name; therefore, shorter names are preferred.
65
66
67
*  Radius = 0.0009 m covers about the whole grid.
68
69
70
*  Mosaic center = stage center
71
72
73
74
75
76
77
78
*  Square Targeting/Settings> Ignore all settings. No need to set these general targeting finding configuration
79
80
81
*  Square Targeting/Mosaic Settings>
82
83
84
85
86
87
*  Calibration Parameter = stage model position
88
89
90
*  Scale Image = yes (default)
91
92
93
*  Scale Image pixel size = 512 (or the size of the grid image that will be used to build the atlas). A larger value can be used in future loading of the tile list.
94
95
96
97
98
*  Hole Targeting/Settings and Exposure Targeting/Settings>
99
100
101
102
*  Allow for user verification of picked holes = yes
103
104
105
*  Queue up targets= no
106
107
108
*  Declare drift when queue is submitted = yes (default)
109
110
111
*  Skip auto picking of holes = yes (change to No after proper setup of the hole-finding algorithm)
112
113
114
115
116
117
*  Focus/Settings> and Z Focus/Settings>
118
119
120
121
*  Acuire post-focus image = yes
122
123
124
*  Melt time = 0 second (should be customized for each grid)
125
126
127
128
129
130
*  Focus/Focus Sequence>
131
132
Enter 3 focus steps in the sequence list box by typing the name in the entry box and press "+" on its right.
133
134
135
Select individual step in the list box and set the following parameters
136
137
138
139
|_.Step:|_.preset:|_.focus method:|_.correction type:|_.Enabled:|
140
|Z_to_Eucentric|fa|Beam Tilt|Stage Z|No|
141
|Def_to_Eucentric|fa|Beam Tilt|Defocus|Yes|
142
|Manual_after|fc|Manual|N/A|Yes|
143
144
145
146
147
For both autofocus steps:
148
*  Tilt = 0.01 radian each direction
149
150
151
*  Image registration = phase correlation
152
153
154
*  Fit limit = 1000
155
156
157
*  Correct for delta Defocus/Z between 0 and 2e-5 meters
158
159
160
*  Check drift greater than 3e-10 meters/s (should be customized by the user based on the exposure time and required resolution).
161
162
163
*  Stigmator correction = No (typical) Yes (if well calibrated)
164
165
166
*  Stigmator Defocus Min = 2e-06 meters
167
168
169
*  Stigmator Defocus Max = 4e-06 meters
170
171
172
173
174
175
*  Z Focus/Focus Sequence>
176
177
The setup here works well for holey carbon grids. Continuous carbon with negative stain may require a different Z Focus Sequence because its low contrast at intermediate mag. See the Chapter on <link linkend="MSI-R_auto_focus">MSI-Raster application regarding improving autofocus</link>.
178
179
Enter 2 focus step in the sequence list box by typing the name in the entry box and press "+" on its right.
180
181
182
Select individual step in the list box and set the following parameters
183
184
185
186
|_.Step:|_.preset:|_.focus method:|_.Enabled:|
187
|Stage_Wobble|sq|Stage Tilt|No|
188
|Z_to_Eucentric|hl|Beam Tilt|Yes|
189
|Manual_after|fc or hl*|Manual|Yes|
190
191
192
193
194
*Use hl if your z focus target will be at the center of a hole where its fft image don't have obvious Thone rings. Use fc if the target is on the carbon film for better accuracy.
195
196
197
For "Stage_Wobble" Step:
198
*  Tilt = 2 degrees each direction
199
200
201
*  Image registration= phase correlation
202
203
204
*  Fit limit = N/A
205
206
207
*  Correct for delta Defocus/Z between 0 and 0.0002 meters
208
209
210
*  Correction type = Stage Z
211
212
213
*  Check drift greater than 3e-10 meters/s = No
214
215
216
*  Stigmator correction = No
217
218
219
*  Stigmator Defocus Max/Min = N/A
220
221
222
223
224
225
For "Z_to_Eucentric" Step:
226
*  Tilt = 0.01 radian each direction
227
228
229
*  Image registration= phase correlation
230
231
232
*  Fit limit = 1500
233
234
235
*  Correct for delta Defocus/Z between 0 and 0.0002 meters
236
237
238
*  Correction type = Stage Z
239
240
241
*  Reset defocus = Default
242
243
244
*  Check drift greater than 3e-10 meters/s = No
245
246
247
*  Stigmator correction = No
248
249
250
*  Stigmator Defocus Max/Min = N/A
251 2 Amber Herold
252
253
254
______
255
256
[[MSI-Tomography Preferences|MSI-Tomography Preferences >]]
257
258
______