New dbemtool Web Tool Features (151) » History » Version 1
  Amber Herold, 04/14/2010 03:30 PM 
  
| 1 | 1 | Amber Herold | h1. New dbemtool Web Tool Features (151) | 
|---|---|---|---|
| 2 | |||
| 3 | |||
| 4 | |||
| 5 | |||
| 6 | h2. Hide or exemplify an image in the viewers | ||
| 7 | |||
| 8 | |||
| 9 | |||
| 10 | Images can be one of the three status: Normal, Hidden, or Exemplar. Clicking on the hide | ||
| 11 | button above the displayed image where it is available moves the image from its current | ||
| 12 | list. In other words, to hide an image from any of the normal preset list, click on "hide" | ||
| 13 | while display a normal image. This image will now display only if "hidden" is selected from | ||
| 14 | the preset list. Clicking on "hide" above an image displayed in the hidden list removes it | ||
| 15 | from the "hidden" list and return it back to the normal list. Images put in the "exemplar" | ||
| 16 | list will also be shown in the normal list. | ||
| 17 | |||
| 18 | |||
| 19 | |||
| 20 | |||
| 21 | |||
| 22 | h2. The mrc images are cached as jpegs in the viewers | ||
| 23 | |||
| 24 | |||
| 25 | |||
| 26 | The cache system allows faster access to the same image next time. | ||
| 27 | |||
| 28 | |||
| 29 | |||
| 30 | |||
| 31 | |||
| 32 | h2. More options for image display intensity adjustment | ||
| 33 | |||
| 34 | |||
| 35 | |||
| 36 | You can manually define min/max of the display range in absolute number or relative | ||
| 37 | percentage, as well as in standard deviation unit based on the statistics of the image. The | ||
| 38 | manually determined values are saved for individual image displayed in the same panel until | ||
| 39 | the page is closed. | ||
| 40 | |||
| 41 | |||
| 42 | |||
| 43 | |||
| 44 | |||
| 45 | h2. Queue counter in LOI | ||
| 46 | |||
| 47 | |||
| 48 | |||
| 49 | It updates the number of unprocessed queue targets and estimate how much time it will | ||
| 50 | still take to finish them. | ||
| 51 | |||
| 52 | |||
| 53 | |||
| 54 | |||
| 55 | |||
| 56 | h2. Queue deletion tool in 3-way and LOI viewers | ||
| 57 | |||
| 58 | |||
| 59 | |||
| 60 | Click on this tool<inlinegraphic | ||
| 61 | fileref="http://emg.nysbc.org/software/leginon/images/images/deq_bt_off.gif" | ||
| 62 | format="GIF"/> above a displayed image pops up a window where you can remove targets | ||
| 63 | derived from that and all its descendent images. In other words. if you have put in the | ||
| 64 | queue targets from 10 holes, each selected from the same square image, you will delete all | ||
| 65 | theses targets if you perform queue deletion on the square image. Please use this | ||
| 66 | carefully. | ||
| 67 | |||
| 68 | |||
| 69 | |||
| 70 | |||
| 71 | |||
| 72 | h2. Hole template and 2-way viewers | ||
| 73 | |||
| 74 | |||
| 75 | |||
| 76 | You can see your custom hole templates saved and used in the past leginon sessions in | ||
| 77 | the hole template viewer. 2-way viewer gives you a bigger view of the parent images than the | ||
| 78 | 3-way viewer. | ||
| 79 | |||
| 80 | |||
| 81 | |||
| 82 | |||
| 83 | |||
| 84 | h2. Model parameter display in the tomography viewer | ||
| 85 | |||
| 86 | |||
| 87 | |||
| 88 | The model paramters can be displayed for diagnosis by activating the check box. | ||
| 89 | |||
| 90 | |||
| 91 | |||
| 92 | |||
| 93 | |||
| 94 | h2. Deletion candidate marking in the tomography viewer | ||
| 95 | |||
| 96 | |||
| 97 | |||
| 98 | The "Mark for deletion" button saves the selected tilt series in the leginon database in | ||
| 99 | a table that the system administrator can look up and delete from the file server in a later | ||
| 100 | time. | ||
| 101 | |||
| 102 | |||
| 103 | |||
| 104 | |||
| 105 | |||
| 106 | h2. Appion processing function possible with installation | ||
| 107 | |||
| 108 | |||
| 109 | |||
| 110 | If you install Appion's processing server programs, the processing tag direct you to its | ||
| 111 | menu page. |