Project

General

Profile

Queuing Example 3 - Both Exposure and Hole Targeting » History » Version 7

Amber Herold, 06/22/2010 02:06 PM

1 1 Amber Herold
h1. Queuing Example 3 - Both Exposure and Hole Targeting
2
3
4
5
MSI-Tomography application is an example of such queuing set up. It is also the useful
6
when energy filter is used. It is chosen so that the microscope stays at the same presets as
7
long as possible to obtain all the images so that LM preset sq will not need to be used once
8
tomography data collection starts.
9
10
11
12
h2. Configuration
13
14
15
16
17
18 4 Amber Herold
1.  /Square/Toolbar/Setup/Wait for a node to process image = no
19 1 Amber Herold
20
21 4 Amber Herold
The "no" setting saves time by acquiring images while holefinder and YOU are picking targets.
22 1 Amber Herold
23
24 5 Amber Herold
2.  /Hole Targeting/Toolbar/Setup/Queue up targets = yes.
25 1 Amber Herold
26
27 4 Amber Herold
3.  /Hole Targeting/Toolbar/Setup/Allow user verification of the selected targets=yes, if desired.
28 1 Amber Herold
29
30 4 Amber Herold
4.  /Hole/Toolbar/Setup/Wait for a node to process image = no.
31 1 Amber Herold
32
33 5 Amber Herold
5.  /Exposure Targeting/Toolbar/Setup/Queue up targets = yes.
34 1 Amber Herold
35
36 5 Amber Herold
6.  /Exposure Targeting/Toolbar/Setup/Allow user verification of the selected targets = yes, if desired.
37 1 Amber Herold
38
39
40
41
h2. Operation
42
43
44
45 4 Amber Herold
1.  Select square targets on grid atlas and submit as usual.
46 1 Amber Herold
47
48 4 Amber Herold
2.  All sq images will be acquired while "Hole Targeting" finds the targets on each sq
49 1 Amber Herold
image since waiting in "Square" node is off. Note that since the square node acquires
50
images continuously, both hole finding and acquisition may compete for processing and
51
memory time. If it affects your interaction with the program, just wait for the
52
acquisition to complete.
53
54
55 4 Amber Herold
3.  If you have just acquired many (such as 50) sq images in LM mode, the microscope
56 1 Amber Herold
has stayed in LM for a long time. It is advisable to set the instrument to one of the
57
preset in HM mode as soon as the acquisitions are completed and check for possible image
58
shift inconsistency between presets. If energy filter need to be on for higher
59
magnification imaging, do so now.
60
61
62 4 Amber Herold
4.  If user verification is turned on in "Hole Targeting", the targets should be
63
submitted using "submit" !http://emg.nysbc.org/software/leginon/images/icons/play.png! tool.
64 1 Amber Herold
65
66 4 Amber Herold
5.  The Queue is submitted and processed only when "Submit Queued Target" !http://emg.nysbc.org/software/leginon/images/icons/send_queue_out.png! tool is clicked.
67 1 Amber Herold
68
69 4 Amber Herold
6.  Repeat the same target selection and submission process at "Exposure Targeting" node.
70 1 Amber Herold
71
72 6 Amber Herold
7.  In case when leginon crashes during queue processing, the data acquisition should be resumed by 
73 7 Amber Herold
"Submit Queued Target" !http://emg.nysbc.org/software/leginon/images/icons/send_queue_out.png! in 
74
"Exposure Targeting" node first. If nothing happens, it means the queue in that node is empty. In that case, repeat it in "Hole Targeting" to resume.
75 1 Amber Herold
76
77
78
h2. Interruption
79
80
81
82 4 Amber Herold
Once the queue is submitted there are several modes of interruption:
83 1 Amber Herold
84
85 4 Amber Herold
1.  If leginon crashes during queue processing, the data queue acquisition can be
86 1 Amber Herold
resumed by "Submit Queued Target" in first the "Exposure Targeting Q" node, then if
87 3 Anchi Cheng
nothing happens, in the "Hole Targeting" node.
88 1 Amber Herold
89
90 4 Amber Herold
2.  Queued targets from "Hole Targeting" can be paused in "Hole" node with "pause"
91 1 Amber Herold
button and is [[Pausing and Aborting during data collection|recommanded for the liquid nitrogen refill of the side-entry cryo stage]].
92
93
94 4 Amber Herold
3.  The "Abort" button !http://emg.nysbc.org/software/leginon/images/icons/stop.png!
95 1 Amber Herold
in "Hole" node aborts the acquisition of the remaining targets from the same parent "hl"
96
image and proceeds to process targets from next square in the queue.
97
98
99 4 Amber Herold
4.  The "Abort Queue" button !http://emg.nysbc.org/software/leginon/images/icons/stop_queue.png! in "Hole" node aborts all remaining targets in the queue.
100 1 Amber Herold
101
102 4 Amber Herold
5.  Exposure targets are paused and aborted in a way similar to the queued Hole Targets.
103 2 Amber Herold
104
105
106
______
107
108
[[Queuing Example 2 - Hole Targeting only|< Queuing Example 2 - Hole Targeting only]] | [[Monitor Progress of Queued Targets|Monitor Progress of Queued Targets >]]
109
110
______