Run Leginon Client on the Instrument Computers » History » Version 8
Anchi Cheng, 06/06/2012 06:43 PM
1 | 1 | Amber Herold | h1. Run Leginon Client on the Microscope Computer |
---|---|---|---|
2 | |||
3 | 3 | Anchi Cheng | Leginon Client is run on the microscope-controlling computer (and the robot controlling computer, if applicable) so that the main Leginon program on the remote computer can launch the necessary node at the right place. For example, in order for the remote computer to get and set microscope parameters, the Instrument node need to be launched on the microscope-controlling computer. Before starting Leginon Client, check that your camera controlling software is set up properly for Leginon interaction: |
4 | 1 | Amber Herold | |
5 | |||
6 | 3 | Anchi Cheng | h2. Using a Gatan Camera |
7 | 1 | Amber Herold | |
8 | 4 | Amber Herold | # Open Digital Micrograph (or check that the Tietz software is closed). |
9 | |
||
10 | # insert the Gatan CCD in Digital Micrograph. |
||
11 | 1 | Amber Herold | |
12 | 3 | Anchi Cheng | |
13 | 1 | Amber Herold | h2. Using a Tietz Camera |
14 | 3 | Anchi Cheng | |
15 | 4 | Amber Herold | # Close Tietz TCL program |
16 | |
||
17 | # Put camera switch box to select CCD. |
||
18 | 1 | Amber Herold | |
19 | 8 | Anchi Cheng | h2. Using a Direct Electron DE-12 Camera |
20 | |||
21 | 7 | Anchi Cheng | # Start DirectElectronAPI.exe and MicroManager |
22 | |
||
23 | # Set the desired *Frames Per Second* and cool down the camera to the desired temperature in MicroManager |
||
24 | |
||
25 | # Close MicroManager but leave DirectElectronAPI.exe running |
||
26 | 1 | Amber Herold | |
27 | |||
28 | 3 | Anchi Cheng | h2. Start Leginon Client |
29 | 1 | Amber Herold | |
30 | |||
31 | 3 | Anchi Cheng | * scope> Start Leginon Client (Either with the shortcut on the Desktop or follow the Start Menu-\Start\Programs\Leginon>Leginon Client) |
32 | 1 | Amber Herold | |
33 | |||
34 | * During Leginon run an Application Error Message may pop up saying |
||
35 | |||
36 | 3 | Anchi Cheng | <pre> |
37 | 1 | Amber Herold | |
38 | 3 | Anchi Cheng | Exception EAccessViolation in module adaExp.exe at .... |
39 | 1 | Amber Herold | |
40 | |||
41 | 3 | Anchi Cheng | Access violation at address xxxx in module 'adaExp.exe'. Read of address xxxx" |
42 | 1 | Amber Herold | |
43 | 3 | Anchi Cheng | </pre> |
44 | 1 | Amber Herold | |
45 | 2 | Amber Herold | Do NOT touch this message box, or leginon client will need restarting. |
46 | |||
47 | 6 | Anchi Cheng | h2. If the camera is controlled separately from the scope host, Start Leginon Client there, too. |
48 | |||
49 | See [[Using_Leginon_on_a_system_where_the_microscope_and_camera_are_controlled_by_different_computers]]. |
||
50 | 2 | Amber Herold | ______ |
51 | |||
52 | [[Test Network Connection Between Remote and Microscope Computers|< Test Network Connection Between Remote and Microscope Computers]] | [[Start Leginon at your main working station remotely|Start Leginon at your main working station remotely >]] |
||
53 | |||
54 | 1 | Amber Herold | ______ |