Project

General

Profile

Summary of this application - MSI-RCT » History » Version 10

Anchi Cheng, 07/05/2013 02:46 PM

1 4 Amber Herold
h1. Summary of these Applications
2 1 Amber Herold
3 2 Amber Herold
4
Random conical tilt (RCT) and orthogonal tilt reconstruction (OTR) image acquisition schemes require images pairs taken at two different tilt angles. The two Leginon "MSI-RCT" applications replace the Exposure node with a specialized node that acquire a batch of targets at one tilt and then the other. A feature matching algorithm is used to transform targets from the selected targets on one parent image at one tilt to the other tilt (and more tilts if needed).
5
6
The two applications differ in the target finding nodes. Therefore, MSI-RCT is suitable for specimen suspended in regular holes from support film such as Quantifoil and C-flat. MSI-RCT-raster is suitable for specimen lay down on continuous carbon film
7
8 5 Anchi Cheng
See [[JAHC_finder_nodes_set-up]] and [[Raster_finder_nodes_set-up]] on how to setup automated targetfinders in the two cases.
9
10
11 2 Amber Herold
Reference "MSI in general" chapter for help on the entire process of setting up . The main difference is that the preset used to acquire the parent image of RCT targeting is set at a magnification in the HM mode to give large viewing area and offer the stronger feature contrast needed for the target transformation between tilts.
12
13 10 Anchi Cheng
h2. [[RCT node set-up|RCT nodes set-up]]: A short guide to set-up the raster finder nodes in the MSI raster Leginon application.
14
15 7 Anchi Cheng
h2. Further reading
16 5 Anchi Cheng
17 3 Amber Herold
[[Pre-MSI Set-up|Pre-MSI Set-up]]: Prior to setting up Leginon for the day, make sure that Leginon has been previously set-up (this step is in case the ambitious user decides to proceed to this section for the first time and hasn't gone through all the calibrations...).
18 2 Amber Herold
19 3 Amber Herold
[[Initial MSI application preference setup|MSI preference & configuration]]: The comprehensive MSI preferences and configuration example. The node name change in MSI raster are: "Hole Targeting" -> "Square Centering", "Hole" -> "Centered Square", "Exposure Targeting" -> "RCT Targeting", "Focus" ->"RCT Focus", and "Exposure" ->"RCT".
20 2 Amber Herold
21 3 Amber Herold
[[MSI Quick-start|MSI Quick Start checklist]]: A short check list for users who are familiar with the application and have saved preferences.
22 2 Amber Herold
23 5 Anchi Cheng
[[MSI set-up in more details|MSI set-up in more details]]: The more complicated MSI Leginon application set-up that should be completed before collecting data.
24 2 Amber Herold
25 6 Anchi Cheng
[[Queuing option]]: "RCT Targeting" node is operated in queuing mode.
26
27
[[Iterative Stage Movement]]: "RCT" node target centering uses this option.
28 2 Amber Herold
29 3 Amber Herold
[[Trouble shooting|Trouble shooting]]: This trouble shooting sections addresses some of the possible challenges a Leginon user may face.
30 1 Amber Herold
31 9 Anchi Cheng
[[RCT run protocol from a user]]
32 2 Amber Herold
33 1 Amber Herold
______
34
35
[[RCT node set-up|RCT node set-up >]]
36
37
______