Summary of this application - MSI-RCT » History » Version 2
Amber Herold, 06/21/2010 02:49 PM
| 1 | 1 | Amber Herold | h1. Summary of this application - MSI-RCT |
|---|---|---|---|
| 2 | |||
| 3 | 2 | Amber Herold | |
| 4 | Random conical tilt (RCT) and orthogonal tilt reconstruction (OTR) image acquisition schemes require images pairs taken at two different tilt angles. The two Leginon "MSI-RCT" applications replace the Exposure node with a specialized node that acquire a batch of targets at one tilt and then the other. A feature matching algorithm is used to transform targets from the selected targets on one parent image at one tilt to the other tilt (and more tilts if needed). |
||
| 5 | |||
| 6 | The two applications differ in the target finding nodes. Therefore, MSI-RCT is suitable for specimen suspended in regular holes from support film such as Quantifoil and C-flat. MSI-RCT-raster is suitable for specimen lay down on continuous carbon film |
||
| 7 | |||
| 8 | Reference "MSI in general" chapter for help on the entire process of setting up . The main difference is that the preset used to acquire the parent image of RCT targeting is set at a magnification in the HM mode to give large viewing area and offer the stronger feature contrast needed for the target transformation between tilts. |
||
| 9 | |||
| 10 | Pre-MSI Set-up: Prior to setting up Leginon for the day, make sure that Leginon has been previously set-up (this step is in case the ambitious user decides to proceed to this section for the first time and hasn't gone through all the calibrations...). |
||
| 11 | |||
| 12 | MSI preference & configuration: The comprehensive MSI preferences and configuration example. The node name change in MSI raster are: "Hole Targeting" -> "Square Centering", "Hole" -> "Centered Square", "Exposure Targeting" -> "RCT Targeting", "Focus" ->"RCT Focus", and "Exposure" ->"RCT". |
||
| 13 | |||
| 14 | MSI Quick Start checklist: A short check list for users who are familiar with the application and have saved preferences. |
||
| 15 | |||
| 16 | MSI set-up in more details: The more complicated MSI Leginon application set-up that should be completed before collecting data. |
||
| 17 | |||
| 18 | Queuing option: "RCT Targeting" node is operated in queuing mode. |
||
| 19 | |||
| 20 | Trouble shooting: This trouble shooting sections addresses some of the possible challenges a Leginon user may face. |
||
| 21 | |||
| 22 | In this chapter: |
||
| 23 | |||
| 24 | RCT nodes set-up: A short guide to set-up the raster finder nodes in the MSI raster Leginon application. |
||