2 | 1 | Amber Herold | |
3 | 2 | Amber Herold | |
4 | Random conical tilt (RCT) and orthogonal tilt reconstruction (OTR) image acquisition schemes require images pairs taken at two different tilt angles. The two Leginon "MSI-RCT" applications replace the Exposure node with a specialized node that acquire a batch of targets at one tilt and then the other. A feature matching algorithm is used to transform targets from the selected targets on one parent image at one tilt to the other tilt (and more tilts if needed). |
||
5 | |||
6 | The two applications differ in the target finding nodes. Therefore, MSI-RCT is suitable for specimen suspended in regular holes from support film such as Quantifoil and C-flat. MSI-RCT-raster is suitable for specimen lay down on continuous carbon film |
||
7 | |||
8 | 5 | Anchi Cheng | See [[JAHC_finder_nodes_set-up]] and [[Raster_finder_nodes_set-up]] on how to setup automated targetfinders in the two cases. |
9 | |||
10 | |||
11 | 2 | Amber Herold | Reference "MSI in general" chapter for help on the entire process of setting up . The main difference is that the preset used to acquire the parent image of RCT targeting is set at a magnification in the HM mode to give large viewing area and offer the stronger feature contrast needed for the target transformation between tilts. |
12 | |||
13 | 5 | Anchi Cheng | |
14 | 3 | Amber Herold | [[Pre-MSI Set-up|Pre-MSI Set-up]]: Prior to setting up Leginon for the day, make sure that Leginon has been previously set-up (this step is in case the ambitious user decides to proceed to this section for the first time and hasn't gone through all the calibrations...). |
15 | 2 | Amber Herold | |
16 | 3 | Amber Herold | [[Initial MSI application preference setup|MSI preference & configuration]]: The comprehensive MSI preferences and configuration example. The node name change in MSI raster are: "Hole Targeting" -> "Square Centering", "Hole" -> "Centered Square", "Exposure Targeting" -> "RCT Targeting", "Focus" ->"RCT Focus", and "Exposure" ->"RCT". |
17 | 2 | Amber Herold | |
18 | 3 | Amber Herold | [[MSI Quick-start|MSI Quick Start checklist]]: A short check list for users who are familiar with the application and have saved preferences. |
19 | 2 | Amber Herold | |
20 | 3 | Amber Herold | [[MSI set-up in more details|MSI set-up in more details]]: The more complicated MSI Leginon application set-up that should be completed before collecting data. |
21 | 5 | Anchi Cheng | |
22 | 2 | Amber Herold | |
23 | 6 | Anchi Cheng | [[Queuing option]]: "RCT Targeting" node is operated in queuing mode. |
24 | |||
25 | [[Iterative Stage Movement]]: "RCT" node target centering uses this option. |
||
26 | 2 | Amber Herold | |
27 | 3 | Amber Herold | [[Trouble shooting|Trouble shooting]]: This trouble shooting sections addresses some of the possible challenges a Leginon user may face. |
28 | 2 | Amber Herold | |
29 | In this chapter: |
||
30 | |||
31 | 3 | Amber Herold | [[RCT node set-up|RCT nodes set-up]]: A short guide to set-up the raster finder nodes in the MSI raster Leginon application. |
32 | 2 | Amber Herold | |
33 | NOTE: The Tietz imaging software (EMMenu) must be turned OFF before Leginon is started. In contrast to this, the Gatan imaging software (Digital Micrograph) must be ON before Leginon is started. |
||