Summary of this application - MSI-RCT » History » Version 8

Neil Voss, 11/12/2012 04:14 PM

1 4 Amber Herold
h1. Summary of these Applications
2 1 Amber Herold
3 2 Amber Herold
4
Random conical tilt (RCT) and orthogonal tilt reconstruction (OTR) image acquisition schemes require images pairs taken at two different tilt angles. The two Leginon "MSI-RCT" applications replace the Exposure node with a specialized node that acquire a batch of targets at one tilt and then the other. A feature matching algorithm is used to transform targets from the selected targets on one parent image at one tilt to the other tilt (and more tilts if needed).
5
6
The two applications differ in the target finding nodes. Therefore, MSI-RCT is suitable for specimen suspended in regular holes from support film such as Quantifoil and C-flat. MSI-RCT-raster is suitable for specimen lay down on continuous carbon film
7
8 5 Anchi Cheng
See [[JAHC_finder_nodes_set-up]] and [[Raster_finder_nodes_set-up]] on how to setup automated targetfinders in the two cases.
9
10
11 2 Amber Herold
Reference "MSI in general" chapter for help on the entire process of setting up . The main difference is that the preset used to acquire the parent image of RCT targeting is set at a magnification in the HM mode to give large viewing area and offer the stronger feature contrast needed for the target transformation between tilts.
12
13 7 Anchi Cheng
h2. Further reading
14 5 Anchi Cheng
15 3 Amber Herold
[[Pre-MSI Set-up|Pre-MSI Set-up]]: Prior to setting up Leginon for the day, make sure that Leginon has been previously set-up (this step is in case the ambitious user decides to proceed to this section for the first time and hasn't gone through all the calibrations...).
16 2 Amber Herold
17 3 Amber Herold
[[Initial MSI application preference setup|MSI preference & configuration]]: The comprehensive MSI preferences and configuration example. The node name change in MSI raster are: "Hole Targeting" -> "Square Centering", "Hole" -> "Centered Square", "Exposure Targeting" -> "RCT Targeting", "Focus" ->"RCT Focus", and "Exposure" ->"RCT".
18 2 Amber Herold
19 3 Amber Herold
[[MSI Quick-start|MSI Quick Start checklist]]: A short check list for users who are familiar with the application and have saved preferences.
20 2 Amber Herold
21 5 Anchi Cheng
[[MSI set-up in more details|MSI set-up in more details]]: The more complicated MSI Leginon application set-up that should be completed before collecting data.
22 2 Amber Herold
23 6 Anchi Cheng
[[Queuing option]]: "RCT Targeting" node is operated in queuing mode.
24
25
[[Iterative Stage Movement]]: "RCT" node target centering uses this option.
26 2 Amber Herold
27 3 Amber Herold
[[Trouble shooting|Trouble shooting]]: This trouble shooting sections addresses some of the possible challenges a Leginon user may face.
28 2 Amber Herold
29 8 Neil Voss
[[RCT run protocol from a user]]
30
31 2 Amber Herold
In this chapter:
32
33 3 Amber Herold
[[RCT node set-up|RCT nodes set-up]]: A short guide to set-up the raster finder nodes in the MSI raster Leginon application.
34 2 Amber Herold
35
NOTE: The Tietz imaging software (EMMenu) must be turned OFF before Leginon is started. In contrast to this, the Gatan imaging software (Digital Micrograph) must be ON before Leginon is started.