Project

General

Profile

Test Leginon with Simulator » History » Version 12

Amber Herold, 06/23/2010 03:18 PM

1 1 Amber Herold
h1. Test Leginon with Simulator
2
3
4
5
h2. Test Leginon with Simulator
6
7
8
9
TEM and CCD simulators are created automatically on the computer Leginon program started
10
at. They are convenient as a way to look around the GUI to try out buttons. The images
11
"acquired" are just random squares on background. Here we will use them to test the database
12
connection and storage disk mapping.
13
14
15
16
h2. Start Leginon on the computer you will run most of the process
17
18
19
20
21
22 12 Amber Herold
* Register as a Leginon user and then copy and personalize your configuration file before your first use.
23
**  First User: Refer to Installation Guide [[Administration Tools|Chapter on Administration Tools]]
24
**  Later Users: Refer to [[Set up for a new regular user|Set up for a new regular user]] in "Administration Tools" Chapter.
25 1 Amber Herold
26
*  start-leginon.py (From any directory for Linux)
27
OR
28
from Start Menu: \Start\Programs\Leginon> Leginon (on Windows)
29
30
31 12 Amber Herold
*  Leginon Setup Wizard> select "Create session" in session type if a new session is needed.
32
**  Fill in session name and comments. Comments will appear in the Web Viewers
33
**  Select instrument and project, if project database is used. Image path is automatically selected.
34
**  Image path is automatically selected based on your leginon.cfg file.
35 1 Amber Herold
36
37 12 Amber Herold
*  Leginon Setup Wizard> No need to edit client list as the computer where the program is started is automated added.
38 1 Amber Herold
39
40
*  Choose "Finish" in the set up wizard to start the session.
41
42
43
44
h2. Acquiring the first simulated image
45
46
47
48
*  Leginon/Application/Run> select Manual Application.
49
50
51
*  Leginon> From the list of nodes on the left panel, select Manual node.
52
53
54
*  Leginon/Manual> Open the "Setting" tool and configure the settings:
55 12 Amber Herold
** SimuTEM and SimuCCDCamera should be available for selection.
56
** Acquisition/Camera Configuration- use one of the preconfigured selection for binning and size such 512x8.
57
** Save image to the database = yes.
58
** Leave the rest of the configuration as default.
59 1 Amber Herold
60
61 12 Amber Herold
*  You should see your first simulated image acquired through Leginon in the image display panel.
62 1 Amber Herold
63
64
65 7 Alex Kadokura
h2. Check on the Web viewer
66
67 1 Amber Herold
68
69 12 Amber Herold
Follow the [[Using the Web viewer|instruction in Manual Application Chapter]].
70 1 Amber Herold
71
72
h2. Problem solving for the simulation test
73
74
75 9 Alex Kadokura
Most problems regarding this test are caused by bad configuration. You should double
76 10 Alex Kadokura
check your [[Configure leginon.cfg|leginon.cfg]], [[Configure sinedon.cfg|sinedon.cfg]], [[Web Server Installation|config.php]] as outlined in
77 11 Anchi Cheng
complete installation chapter. See [[Test run operation problems|Installation
78 1 Amber Herold
Troubleshooting]], and "leginon Bulletin Board":http://emg.nysbc.org/bb/viewforum.php?f=2 or  "dbemtool Bulletin Board":http://emg.nysbc.org/bb/viewforum.php?f=6  such as the topic " "information not saved to db":http://emg.nysbc.org/bb/viewtopic.php?t=241 "
79
for common problems.
80
81
82 12 Amber Herold
If everything goes smoothly, do a test directly on the computer controlling the microscope as in the next section.
83 2 Amber Herold
84
85
86
______
87
88
[[Test Leginon on the Computer Controlling the Microscope|Test Leginon on the Computer Controlling the Microscope >]]
89
90
______