h1. Test Leginon with Simulator
2
3
4
5
h2. Test Leginon with Simulator
6
7
8
9
TEM and CCD simulators are created automatically on the computer Leginon program started
10
at. They are convenient as a way to look around the GUI to try out buttons. The images
11
"acquired" are just random squares on background. Here we will use them to test the database
12
connection and storage disk mapping.
13
14
15
16 19 Anchi Cheng
h2. Start Leginon on the computer you will run the process
17 1 Amber Herold
18
19
20 15 Amber Herold
# Register as a Leginon user and then copy and personalize your configuration file before your first use.
21 18 Anchi Cheng
** Leginon guru: See [[Recommandation_for_setup_at_a_new_institute|Recommendation for setup at a new institute]]
22 17 Anchi Cheng
** Regular Users: Refer to [[Set up for a new regular user|Set up for a new regular user]] in "Administration Tools" Chapter.
23 15 Amber Herold
 
24
#  start-leginon.py (From any directory for Linux)
25
 
26 14 Amber Herold
OR
27 15 Amber Herold
 
28 14 Amber Herold
from Start Menu: \Start\Programs\Leginon> Leginon (on Windows)
29 15 Amber Herold
 
30
#  Leginon Setup Wizard> select "Create session" in session type if a new session is needed.
31
 
32 1 Amber Herold
**  Fill in session name and comments. Comments will appear in the Web Viewers
33 15 Amber Herold
 
34 1 Amber Herold
**  Select instrument and project, if project database is used. Image path is automatically selected.
35 15 Amber Herold
 
36 1 Amber Herold
**  Image path is automatically selected based on your leginon.cfg file.
37 15 Amber Herold
 
38
#  Leginon Setup Wizard> No need to edit client list as the computer where the program is started is automated added.
39
 
40
#  Choose "Finish" in the set up wizard to start the session.
41 1 Amber Herold
42
43
44
h2. Acquiring the first simulated image
45
46
47
48 15 Amber Herold
#  Leginon/Application/Run> select Manual Application.
49
 
50
#  Leginon> From the list of nodes on the left panel, select Manual node.
51
 
52
#  Leginon/Manual> Open the "Setting" tool and configure the settings:
53
 
54 1 Amber Herold
** SimuTEM and SimuCCDCamera should be available for selection.
55 15 Amber Herold
 
56 12 Amber Herold
** Acquisition/Camera Configuration- use one of the preconfigured selection for binning and size such 512x8.
57 15 Amber Herold
 
58 12 Amber Herold
** Save image to the database = yes.
59 15 Amber Herold
 
60 1 Amber Herold
** Leave the rest of the configuration as default.
61 15 Amber Herold
 
62
 
63
#  You should see your first simulated image acquired through Leginon in the image display panel.
64 1 Amber Herold
65
66 7 Alex Kadokura
67
h2. Check on the Web viewer
68 1 Amber Herold
69
70 12 Amber Herold
71 1 Amber Herold
Follow the [[Using the Web viewer|instruction in Manual Application Chapter]].
72
73
74
h2. Problem solving for the simulation test
75
76 9 Alex Kadokura
77 10 Alex Kadokura
Most problems regarding this test are caused by bad configuration. You should double
78 11 Anchi Cheng
check your [[Configure leginon.cfg|leginon.cfg]], [[Configure sinedon.cfg|sinedon.cfg]], [[Web Server Installation|config.php]] as outlined in
79 1 Amber Herold
complete installation chapter. See [[Test run operation problems|Installation
80 16 Amber Herold
Troubleshooting]], and the "Leginon Forum":http://emg.nysbc.org/projects/leginon/boards/6 or  "Web Tools Forum":http://emg.nysbc.org/projects/leginon/boards/10  such as the topic " "information not saved to db":http://emg.nysbc.org/boards/10/topics/686"
81 1 Amber Herold
for common problems.
82
83 12 Amber Herold
84 2 Amber Herold
If everything goes smoothly, do a test directly on the computer controlling the microscope as in the next section.