Project

General

Profile

Test Leginon with Simulator » History » Version 3

Alex Kadokura, 05/26/2010 12:16 PM

1 1 Amber Herold
h1. Test Leginon with Simulator
2
3
4
5
h2. Test Leginon with Simulator
6
7
8
9
TEM and CCD simulators are created automatically on the computer Leginon program started
10
at. They are convenient as a way to look around the GUI to try out buttons. The images
11
"acquired" are just random squares on background. Here we will use them to test the database
12
connection and storage disk mapping.
13
14
15
16
h2. Start Leginon on the computer you will run most of the process
17
18
19
20
21
22 3 Alex Kadokura
* h3. Register as a Leginon user and then copy and personalize your configuration
23
file before your first use.
24 1 Amber Herold
*  First User: Refer to Installation Guide <link linkend="addusers">Chapter on
25
Administration Tools</link>
26
27
28
*  Later Users: Refer to "<link linkend="admin_adduser">Set up for a new
29
regular user</link>" in "Administration Tools" Chapter.
30
31
32
33
34
35
36
*  start-leginon.py (From any directory for Linux)
37
38
39
OR
40
41
42
from Start Menu: \Start\Programs\Leginon> Leginon (on Windows)
43
44
45
*  Leginon Setup Wizard> select "Create session" in session type if a new session
46
is needed.
47
48
49
50
51
*  Fill in session name and comments. Comments will appear in the Web
52
Viewers
53
54
55
*  Select instrument and project, if project database is used. Image path is
56
automatically selected.
57
58
59
*  Image path is automatically selected based on your leginon.cfg file.
60
61
62
63
64
65
66
*  Leginon Setup Wizard> No need to edit client list as the computer where the
67
program is started is automated added.
68
69
70
*  Choose "Finish" in the set up wizard to start the session.
71
72
73
74
75
76
77
78
79
80
h2. Acquiring the first simulated image
81
82
83
84
85
86
*  Leginon/Application/Run> select Manual Application.
87
88
89
*  Leginon> From the list of nodes on the left panel, select Manual node.
90
91
92
*  Leginon/Manual> Open the "Setting" tool and configure the settings:
93
94
95
SimuTEM and SimuCCDCamera should be available for selection.
96
97
98
Acquisition/Camera Configuration- use one of the preconfigured selection for
99
binning and size such 512x8.
100
101
102
Save image to the database=yes.
103
104
105
Leave the rest of the configuration to default.
106
107
108
*  You should see your first simulated image acquired through Leginon in the image
109
display panel.
110
111
112
113
114
115
116
117
118
119
h2. Check on the Web viewer
120
121
122
123
Follow the <link linkend="AppManual_webviewer">instruction in Manual Application
124
Chapter</link>.
125
126
127
128
129
130
h2. Problem solving for the simulation test
131
132
133
134
Most problems regarding this test are caused by bad configuration. You should double
135
check your <link linkend="leginon_cfg">leginon.cfg</link>, <link linkend="sinedon_cfg"
136
>sinedon.cfg</link>, <link linkend="install_dbemtool">config.php</link> as outlined in
137
complete installation chapter. See <link linkend="InstT_testrun">Installation
138
Troubleshooting</link>, and  "dbem Bulletin Board":http://emg.nysbc.org/bb/viewforum.php?t=246  such as the topic " "information not saved to db":http://emg.nysbc.org/bb/viewtopic.php?t=241 "
139
for common problems.
140
141
142
If everything goes smoothly, do a test directly on the computer controlling the
143
microscope as in the next section.
144 2 Amber Herold
145
146
147
______
148
149
[[Test Leginon on the Computer Controlling the Microscope|Test Leginon on the Computer Controlling the Microscope >]]
150
151
______