Project

General

Profile

The EM node » History » Version 3

Eric Hou, 06/24/2010 04:59 PM

1 1 Amber Herold
h1. The EM node
2
3 3 Eric Hou
The EM node or tab is the node that is running on the microscope computer. This node is responsible for communicating to the microscope, CCD, and Leginon. Without the EM node, Leginon cannot control the microscope.
4 1 Amber Herold
5
Required bindings: None
6
7
h2. Microscope paramters
8
9
Select TEM to view and sometimes change microscope parameters
10
11
*  Leginon/EM> Do Pauses
12
13 3 Eric Hou
 enabled = pause for example 2s before acquiring an image (pauses set in acquisition nodes)
14 1 Amber Herold
15
*  Leginon/EM> High Tension
16
17
*  Leginon/EM> Magnification
18
19
*  Leginon/EM> Intensity
20
21
*  Leginon/EM> Spot size
22
23
*  Leginon/EM> Lenses: Objective excitation
24
25
*  Leginon/EM> image shift (x, y)
26
27
*  Leginon/EM> image shift raw (x, y)
28
29
*  Leginon/EM> beam shift (x, y)
30
31
*  Leginon/EM> beam tilt (x, y)
32
33
*  Leginon/EM> objective stigmator (x, y)
34
35
*  Leginon/EM> diffraction stigmator (x, y)
36
37
*  Leginon/EM> condensor stigmator (x, y)
38
39
*  Leginon/EM> focus (absolute focus value)
40
41
*  Leginon/EM> defocus (relative focus value)
42
43
*  Leginon/EM> reset defocus (enabling resets the defocus)
44
45
*  Leginon/EM> Vacuum Status
46
47
*  Leginon/EM> Column pressure (in Pa)
48
49
*  Leginon/EM> Column valves ("open" or "closed")
50
51
*  Leginon/EM> Turbo pump ("on" or "off")
52
53 3 Eric Hou
* Leginon/EM> Stage Status ("busy, ready, or unknown", cannot manually adjust)
54 1 Amber Herold
55
*  Leginon/EM> Correct stage movement (enabled)
56
57
*  Leginon/EM> Stage Position x/y/z
58
59
*  Leginon/EM> Angle a/b
60
61
*  Leginon/EM> Film Stock
62
63
*  Leginon/EM> Film Exposure number (of the next exposure)
64
65
*  Leginon/EM> Film Exposure type ("manual")
66
67
*  Leginon/EM> Automatic exposure time (s, based on intensity)
68
69
*  Leginon/EM> Manual exposure time
70
71
*  Leginon/EM> User code (that will appear on the next film exposure)
72
73
*  Leginon/EM> Date Type (YY.MM.DD)
74
75
*  Leginon/EM> Text (additional text to apply to the next film exposure)
76
77
*  Leginon/EM> Shutter (pre-specimen, "open" or "closed")
78
79 3 Eric Hou
*  Leginon/EM> External shutter (post specimen shutter connection, "connected" or "disconnected")
80 1 Amber Herold
81
*  Leginon/EM> Screen Current (mA)
82
83
*  Leginon/EM> Screen Position (Main and Small) ("up" or "down")
84
85
*  Leginon/EM> Holder Status ("inserted" or "not inserted")
86
87 3 Eric Hou
*  Leginon/EM> Holder Type (options "single tilt, no holder, cryo, unknown holder")
88 1 Amber Herold
89
*  Leginon/EM> Lose Dose Status ("on" or "off", default is "off"*)
90
91
*  Leginon/EM> Low Dose Mode ("exposure*, focus, or search")
92
93
*  Leginon/EM> film stock
94
95
h2. Camera parameters
96
97
The current camera parameters are displayed in Leginon/EM>
98
99
Information:
100
101
*  Leginon/EM> binning (x, y)
102
103
*  Leginon/EM> Size (x,y)
104
105
*  Leginon/EM> Pixel size (x,y)
106
107
*  Leginon/EM> Name
108
109
*  Leginon/EM> Chip
110
111
*  Leginon/EM> Serial number
112
113
*  Leginon/EM> Maximum value
114
115
*  Leginon/EM> Live mode
116
117
*  Leginon/EM> Simulation image path
118
119
*  Leginon/EM> Temperature
120
121
*  Leginon/EM> Harware gain index
122
123
*  Leginon/EM> Hardware speed index
124
125
*  Leginon/EM> Retractable
126
127
*  Leginon/EM> Axis
128
129
Settings:
130
131
*  Leginon/EM> Dimension (x, y)
132
133
*  Leginon/EM> Offset (x,y) (from the top left corner of the CCD)
134
135
*  Leginon/EM> Binning (x,y)
136
137
*  Leginon/EM> Pre-configured camera settings
138
139
*  Leginon/EM> Custom configuration
140
141
*  Leginon/EM> Exposure time (ms)
142
143
*  Leginon/EM> Exposure type ("normal" or "dark")
144
145
*  Leginon/EM> Gain index
146
147
*  Leginon/EM> Speed index (the read-out speed of the CCD)
148
149
*  Leginon/EM> Mirror
150
151
*  Leginon/EM> Rotate
152
153
*  Leginon/EM> Shutter open delay
154
155
*  Leginon/EM> Shutter close delay
156
157
*  Leginon/EM> Preamp delay
158
159 2 Amber Herold
*  Leginon/EM> Parallel mode
160
161
162
______
163
164
[[Drift Manager|< Drift Manager]] | [[FFT Maker|FFT Maker >]]
165
166
______