Project

General

Profile

KLH Dataset II » History » Version 33

Eric Hou, 08/25/2010 10:46 AM

1 22 Bridget Carragher
h1. Public Data Sets: KLH2
2 21 Bridget Carragher
3 23 Eric Hou
*KLH Dataset II:* 655 defocus pairs of micrographs, coordinate centers of ~10000 side-view particles, a preliminary 3D reconstruction.
4 1 Eric Hou
5 23 Eric Hou
h2. 1. Images.
6 1 Eric Hou
7 29 Eric Hou
Images were acquired with a FEI Tecnai F20 equipped with a 2Kx2K CCD Tietz camera, as defocal pairs at a nominal magnification of 62,000 x and a voltage of 120 KeV, using the Leginon system ("Potter et al., 1999":http://www.ncbi.nlm.nih.gov/pubmed/10406132 ; "Carragher et al., 2000":http://www.ncbi.nlm.nih.gov/pubmed/11121305). The first image (named *.001.mrc) is acquired at near to focus (NTF) conditions (-0.6 to -1.5 µm) and the second image (named *.002.mrc) at farther from focus (FFF) conditions (-3µm). The time interval between the two exposures is approximately 20s due to the time required to read out the digital image from the camera. The pixel size is 2.2Å at the specimen scale and the accumulated dose for each high magnification image area was ~10 e/Ų. 
8 23 Eric Hou
Below is an example of a defocus pair. Click on the images to see at full scale.
9 2 Eric Hou
10 4 Eric Hou
p=. (a) !fig1a.jpg!:http://emg.nysbc.org/prtl_data/klh/klh_10k/fig1a.jpg           (b) !fig1b.jpg!:http://emg.nysbc.org/prtl_data/klh/klh_10k/fig1b.jpg
11 3 Eric Hou
(a) Near to focus - NTF image. (b) Far from focus - FFF image.
12
13 2 Eric Hou
p=. *Figure 1: An example pair of high magnification images of KLH.*
14
15 27 Eric Hou
*Downloading High Magnification Images:* Image files are provided in "MRC":http://emg.nysbc.org/prtl_data/mrc_specification.htm format and as JPEG files
16 19 Eric Hou
17 33 Eric Hou
Download entire set of images "here":http://emg.nysbc.org/data/02oct09a.tar (~83GB). 
18 6 Eric Hou
19 25 Eric Hou
We suggest using a tool called "em2em":http://www.imagescience.de/em2em, to convert MRC files to other formats.
20
21 2 Eric Hou
22
23 26 Eric Hou
h2. 2. Positions of the Picked Particles in the Images
24 2 Eric Hou
25 26 Eric Hou
Particles are picked in the FFF images and these coordinates are used to select particle in the NTF images. Phase correlation is used to align the two images to calculate the offset between the FFF coordinates and the NTF coordinates. 
26 2 Eric Hou
27 10 Eric Hou
p=. (a) !fig3a.jpg!:http://emg.nysbc.org/prtl_data/klh/klh_10k/fig3a.jpg           (b) !fig3b.jpg!:http://emg.nysbc.org/prtl_data/klh/klh_10k/fig3b.jpg
28 9 Eric Hou
(a) The NTF image. (b) The FFF image.
29
30 2 Eric Hou
p=. *Figure 3: An example pair of images outlined with particles selected by Selexon. Each "+" indicate a detected particle.*
31
32 26 Eric Hou
h2. 2.1 Automated Picking
33 12 Eric Hou
34 30 Eric Hou
The method described in ("Zhu et al., 2003":http://www.ncbi.nlm.nih.gov/pubmed/14643198) was used to select 11309 side-view particles from the FFF images.  Particle coordinates are provide below:
35 14 Eric Hou
36 28 Neil Voss
* "Coordinates":http://emg.nysbc.org/prtl_data/klh/klh_10k/selexon.pik.tar of 11309 side-view particles selected in the FFF images.
37 15 Eric Hou
38 1 Eric Hou
39 26 Eric Hou
h2. 3. 3D Reconstructed Map
40 1 Eric Hou
41 26 Eric Hou
A 3D reconstruction was generated using automatically particles using D5 point-group symmetry and several cycles of refinement.
42 1 Eric Hou
43 28 Neil Voss
* "Coordinates":http://emg.nysbc.org/prtl_data/klh/klh_10k/prtl_in_3dmap.tar of 10997 side-view particles went into the map.