Project

General

Profile

Actions

Bug #562

closed

Focus sequence problem

Added by Matthias Brunner about 14 years ago. Updated over 10 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
-
Start date:
05/25/2010
Due date:
% Done:

0%

Estimated time:
Affected Version:
Appion/Leginon 2.0.1
Show in known bugs:
Yes
Workaround:

Give 2 different names for different sequences.


Description

If you have 2 steps in focus sequence at the same preset (i.e. repeat for better convergence), defocus measurement fails because defocus is not applied for the second stage.
Preset does not change for the second step.

Fix: Force always a preset change in focus sequence.


Related issues 1 (0 open1 closed)

Is duplicate of Leginon - Bug #1569: defocus of the second of two autofocus sequence with the same preset and defocus adjustment is not setClosedJim Pulokas02/29/2012

Actions
Actions

Also available in: Atom PDF