Project

General

Profile

Actions

Bug #2091

open

tomography reconstruction does not have the right pixel size

Added by Anchi Cheng about 12 years ago. Updated about 12 years ago.

Status:
In Code Review
Priority:
Normal
Assignee:
Category:
-
Target version:
-
Start date:
10/10/2012
Due date:
% Done:

0%

Estimated time:
Affected Version:
Appion/Leginon 2.1.0
Show in known bugs:
No
Workaround:

Description

tilt series stack created from Leginon always has pixel size of 1. Need to be updated with the correct pixel size before processed further.

Actions #1

Updated by Anchi Cheng about 12 years ago

  • Status changed from Assigned to In Code Review
  • Assignee changed from Anchi Cheng to Jim Pulokas

Jim,

Assign to me to make Shawn test this.

Anchi

Actions

Also available in: Atom PDF