Align tilt series » History » Version 20
Anke Mulder, 06/07/2010 10:54 AM
1 | 1 | Anke Mulder | h1. Align tilt series |
---|---|---|---|
2 | |||
3 | 10 | Anke Mulder | !http://emg.nysbc.org/attachments/267/Picture_62.png! |
4 | 5 | Anke Mulder | |
5 | 3 | Anke Mulder | h2. General Workflow: |
6 | |||
7 | 18 | Anke Mulder | # Select the tiltseries to align. |
8 | 3 | Anke Mulder | # Check the runname and enter a description. |
9 | 1 | Anke Mulder | # Use the radio button to select Protomo Refinement or IMOD shift-only alignment. |
10 | 4 | Anke Mulder | # To submit the job to the cluster click the "Align Tilt Series" button. Alternatively, click on "Just Show Command" to obtain a command that can be pasted into a UNIX shell. |
11 | 1 | Anke Mulder | !http://emg.nysbc.org/attachments/263/Picture_55.png! |
12 | 8 | Anke Mulder | # If your job has been submitted to the cluster, a page will appear with a link "Check status of job", which allows tracking of the job via its log-file. This link is also accessible from the "1 running" option under the "Aliogn tilt series" submenu in the appion sidebar. |
13 | 12 | Anke Mulder | # Now click on the "1 Complete" link under the "Align tilt series" submenu. This opens a summary of all tilt series alignment runs that have been completed for this dataset. |
14 | 1 | Anke Mulder | !http://emg.nysbc.org/attachments/266/Picture_61.png! |
15 | 12 | Anke Mulder | # Clicking on the "alignrun id" opens a summary page for the alignment cycles that were run. |
16 | 13 | Anke Mulder | # Clicking on the "refine cycle" number opens a report page for that cycle including input parameters and directory paths. Clicking on "Alignment Movie" opens a new web-browser with a movie of the aligned tilt series. |
17 | 19 | Anke Mulder | # The same alignment cycle can be repeated by clicking "Repeat Last Aligner Iteration" or another initiated by clicking "Setup Next Aligner Iteration" (See Step 11 below). |
18 | 17 | Anke Mulder | # In order to [[Create full tomogram|calculate a tomogram]] from the aligned tiltseries, click on the "Create full tomogram" link in the Tomography menu on the Appion Sidebar. |
19 | 1 | Anke Mulder | !http://emg.nysbc.org/attachments/272/Picture_70.png! |
20 | 19 | Anke Mulder | # If you selected "Setup Next Aligner Iteration" in step 9, then: |
21 | |||
22 | 3 | Anke Mulder | |
23 | h2. Notes, Comments, and Suggestions: |
||
24 | |||
25 | 2 | Anke Mulder | |
26 | ______ |
||
27 | |||
28 | [[Tomography|< Tomography]] | [[Create full tomogram|Create Full Tomogram >]] |
||
29 | |||
30 | ______ |