Project

General

Profile

Align tilt series » History » Revision 23

Revision 22 (Anke Mulder, 06/07/2010 11:01 AM) → Revision 23/29 (Anke Mulder, 06/07/2010 12:06 PM)

h1. Align tilt series 

 !http://emg.nysbc.org/attachments/267/Picture_62.png! 

 h2. General Workflow: 

 # Select the tiltseries to align. 
 # Check the runname and enter a description. 
 # Use the radio button to select Protomo Refinement or IMOD shift-only alignment. 
 # To submit the job to the cluster click the "Align Tilt Series" button.    Alternatively, click on "Just Show Command" to obtain a command that can be pasted into a UNIX shell. 
 !http://emg.nysbc.org/attachments/263/Picture_55.png! 
 # If your job has been submitted to the cluster, a page will appear with a link "Check status of job", which allows tracking of the job via its log-file. This link is also accessible from the "1 running" option under the "Aliogn tilt series" submenu in the appion sidebar. 
 # Now click on the "1 Complete" link under the "Align tilt series" submenu. This opens a summary of all tilt series alignment runs that have been completed for this dataset. 
 !http://emg.nysbc.org/attachments/266/Picture_61.png! 
 # Clicking on the "alignrun id" opens a summary page for the alignment cycles that were run. 
 # Clicking on the "refine cycle" number opens a report page for that cycle including input parameters and directory paths.    Clicking on "Alignment Movie" opens a new web-browser with a movie of the aligned tilt series. 
 # The same alignment cycle can be repeated by clicking "Repeat Last Aligner Iteration" or another initiated by clicking "Setup Next Aligner Iteration" (See Step 11 below). 
 # In order to [[Create full tomogram|calculate a tomogram]] from the aligned tiltseries, click on the "Create full tomogram" link in the Tomography menu on the Appion Sidebar. 
 !http://emg.nysbc.org/attachments/272/Picture_70.png! 
 # If you selected "Repeat Last Aligner Iteration or "Setup Next Aligner Iteration" in step 9:    Enter the tilt image that protomo should use as a starting point for refinement during this next round. point.    Note that once you've entered this image number, the corresponding image is surrounded by a blue circle in the tilt-series graph.    If the previous refinement run was good for only a subset of the tiltseries,  
 
 # Enter a description of this run.    For example "repetition of alignrun id 5". 
 # Click "Align Tilt Series" to submit to the cluster.    Alternatively, click "Just Show Command," to copy and paste the command into a unix shell. 
 !http://emg.nysbc.org/attachments/295/Picture_5.png! !http://emg.nysbc.org/attachments/292/Picture_3.png! 


 h2. Notes, Comments, and Suggestions: 


 ______ 

 [[Tomography|< Tomography]] | [[Create full tomogram|Create Full Tomogram >]] 

 ______