Project

General

Profile

Upload More Images » History » Version 7

Anchi Cheng, 10/21/2015 11:13 AM

1 1 Amber Herold
h1. Upload More Images
2
3 2 Pick-Wei Lau
The user is able to upload raw micrographs to either existing or new session to be used in appion processing 
4 1 Amber Herold
5 5 Anke Mulder
h2. General Workflow:
6 1 Amber Herold
7 5 Anke Mulder
*To launch:* 
8
9 7 Anchi Cheng
*Upload More Images Screen*
10 6 Anchi Cheng
!http://emg.nysbc.org/attachments/1351/uploadimage.jpg!
11
12
# For existing session, you can not change session name or description
13 3 Pick-Wei Lau
# The user has the option to select the origin of the micrographs (e.g. tecnai2 on tietz camera)
14
# If it is a tilt series, the user will need to provide the number of images within the tilt series as well as the tilt information in the following parameter file
15
# Following this, the user has the option to upload via specifying a parameter file or enter the parameter manually.
16 1 Amber Herold
17 3 Pick-Wei Lau
h3. Specify a Parameter File:
18
19
# This file has to adhere to the following information:
20
## complete path and name of micrograph 
21
## pixel size in meters [1.63e-10] 
22
## binning in x [1] 
23
## binning in y [1]
24
## nominal scope magnification [50000]
25
## intended defocus in meters [-2e-06]
26
## high tension in volts [200000]
27
## (optional) stage alpha tilt in degrees if loading tilt group [55]
28
# The values for each micrographs should be on the same line separated by tabs: 
29
30
> > /home/abc/xxx.mrc   1.63e-10   1   1   50000    -2e-06   200000   55
31
32
> > /home/abc/xyz.mrc   1.63e-10   1   1   50000    -2e-06   200000   10
33
34
h3. Enter parameters manually:
35
36
# The user provides the path of the directory containing the images
37
# The user provides the file format
38
# The user provides the pixel size of the micrographs in Angstrom
39
# The user provides the binning in x
40
# The user provides the binning in y
41
# The user provides the magnification
42
# The user provides the defocus in micron
43
# The user provides the high tension of the microscope in kV
44
45
46
For a series of untilted images, it might be easier to enter parametes manually (assuming all your micrographs are in the same directory and all the other informations are the same for each image). 
47
48 1 Amber Herold
For tilted images, the user will definiltey need to create a parameter file to incorporate the stage alpha tilt information during upload.
49 2 Pick-Wei Lau
50 5 Anke Mulder
*Output:*
51 2 Pick-Wei Lau
52 4 Pick-Wei Lau
# Once the micrographs are uploaded, it will appear in the viewer by choosing the correct session. 
53 1 Amber Herold
# The user can then start processing the micrographs using appion.
54 4 Pick-Wei Lau
55 5 Anke Mulder
h2. Notes, Comments, and Suggestions:
56 1 Amber Herold
57 5 Anke Mulder
!http://emg.nysbc.org/attachments/277/Picture_81.png!
58 1 Amber Herold
59
______
60
61
[[Upload Model|< Upload Model]] | [[Upload Stack|Upload Stack >]]
62
63
______