Summary of this application - Robot-MSI-Screen » History » Version 8
Anchi Cheng, 07/15/2010 05:11 PM
1 | 1 | Amber Herold | h1. Summary of this application - Robot-MSI-Screen |
---|---|---|---|
2 | |||
3 | |||
4 | |||
5 | |||
6 | "Robot-MSI-Screen" applications are a set of three applications designed for 2D-crystal screening. The screening uses a two-pass approach to reduce screening time on obviously bad trials. A user-interactive evaluation is made between the two automated robotic applications. Please refer to Cheng et. al. (2007) J. Struct. Biology vol.160, 324-331 for detail discussions and timing of the process. |
||
7 | |||
8 | |||
9 | If you don't have a grid insertion robot, you may use this set of application in robot "simulation" mode. However, because human does not repeat placing of the grids on the holder at the same accuracy as the robot, you may have to perform the two passes in tendom of the same grid. |
||
10 | |||
11 | |||
12 | Reference "MSI in general" chapter for help on the entire process of setting up and operation. |
||
13 | |||
14 | |||
15 | 3 | Eric Hou | [[Pre-MSI_Set-up|Pre-MSI Set-up]]: Prior to setting up Leginon for the day, make sure that Leginon has been previously set-up (this step is in case the ambitious user decides to proceed to this section for the first time and hasn't gone through all the calibrations...). |
16 | 1 | Amber Herold | |
17 | |||
18 | 4 | Eric Hou | [[Initial_MSI_application_preferences|Initial_MSI_application_preferences]]: The comprehensive MSI preferences and configuration example. The data flow for RobotMSI-Screen 1st Pass and 2nd Pass are most similar to MSI-Raster application. The default settings loaded at the time of Leginon installation would make the application unique. |
19 | 1 | Amber Herold | |
20 | |||
21 | 5 | Eric Hou | [[MSI_Quick-start|MSI Quick Start checklist]]: A short check list for users who are familiar with MSI applications. |
22 | 1 | Amber Herold | |
23 | |||
24 | 6 | Eric Hou | [[MSI_set-up_in_more_details|MSI set-up in more details]]: The more complicated MSI Leginon application set-up that should be completed before collecting data. |
25 | 1 | Amber Herold | |
26 | |||
27 | 7 | Eric Hou | [[Trouble_shooting|Trouble shooting]]: This trouble shooting sections addresses some of the possible challenges a Leginon user may face. |
28 | 1 | Amber Herold | |
29 | |||
30 | NOTE: The Tietz imaging software (EMMenu) must be turned OFF before Leginon is started. In contrast to this, the Gatan imaging software (Digital Micrograph) must be ON before Leginon is started. |
||
31 | 2 | Amber Herold | |
32 | |||
33 | ______ |
||
34 | |||
35 | 8 | Anchi Cheng | [[Upload Grids|Register the grids in the database >]] |