Feature #503
closed
Report which ace run the values come from when clicking the 'ACE' button in the imageviewer
Added by Bridget Carragher over 14 years ago.
Updated over 14 years ago.
Description
On the summary pages for ace1 the confidence numbers are reported quite low (see: http://cronus3.scripps.edu/myamiweb/processing/ctfreport.php?expId=7647) bit if you look a the ace graphs on the viewer which has the confidence values output the values are as expected quite high.
Also on the summary pages there is a graph of confidence values - which run is this for? Could we have the graph for both and/or label the graph.
- Target version set to Appion/Leginon 2.0.0
- Status changed from New to Assigned
- Assignee set to Eric Hou
The values are always the best reported value in the database. In this case the ACE2 values are great, but the ACE1 values are poor.
Can we report which ace run the values come from when clicking the 'ACE' button in the imageviewer?
- Tracker changed from Bug to Feature
- Subject changed from Ace1 confidence vlaues in report pages are not correct to Report which ace run the values come from when clicking the 'ACE' button in the imageviewer
- Status changed from Assigned to In Code Review
- % Done changed from 0 to 100
- Status changed from In Code Review to In Test
code are good.
ready for test.
- Status changed from In Test to Closed
Right now the correct runname is showing up in the image viewer.
The graph in CTF report shows "Summary of confidence values from all runs"
Thanks.
Eric
Also available in: Atom
PDF