Ace 2 Estimation¶
This algorithm is faster than ACE 1 and includes astigmatism estimation.
General Workflow:¶
- Make sure that appropriate run names and directory trees are specified. Appion increments names automatically, but users are free to specify proprietary names and directories.
- Select the leginon preset corresponding to the images you'd like to process. Generally "_en" images in leginon are the raw micrographs, but uploaded film data will have a different present. Selecting "all" will simply process all images.
- Check boxes allow the option to run Ace 2 concurrently with data collection. "Wait for more images" will wait until collection times out before stopping ACE 2 processing. The "Limit" box allows restrictions on the number of images to process, which is useful when testing parameters initially.
- Radio buttons under "Images to Process" allows a level of pre-processing image filtering. Images that were rejected, hidden, or made exmplars in the image viewer can here be included or exluded.
- Radio buttons under "Image Order" sets the order in which images are processed and radio buttons under "Continuation" gives the option of continuing or rerunning a previous ACE 2 run.
- If you have a previous ACE1 or Ace 2 run, check this box and set a confidence value to reprocess images that scored below that confidence value. Otherwise, leave unchecked.
- Make sure that "Commit to Database" box is checked. (For test runs in which you do not wish to store results in the database this box can be unchecked).
- Click on "Run Ace 2" to submit your job to the cluster. Alternatively, click on "Just Show Command" to obtain a command that can be pasted into a UNIX shell.
- If your job has been submitted to the cluster, a page will appear with a link "Check status of job", which allows tracking of the job via its log-file. This link is also accessible from the "1 running" option under the "Run Ace 2" submenu in the appion sidebar.
- Now click on the "1 Complete" link under the "Run Ace 2" submenu. This opens a summary of all CTF Estimation (Ace 1, Ace 2, CtfFind) runs with a summary histogram of confidence values.
- Clicking on "download ctf data" opens a dialog for exporting CTF Estimation results for use in another application.
- Clicking on the "acerun#" name opens a summary page of the parameters used for the particular run.
- The CTF parameters and astigmatism estimation determined by Ace 2 can be applied to particles during particle boxing in appion with the Create Particle Stack tool.
Notes, Comments, and Suggestions:¶
- Ace 2 is faster than ACE 1
- If multiple CTF estimation runs are performed for a single dataset, the Appion stack creation tool will select the CTF parameters determined with the highest confidence value (regardless of algorithm used) for a particle from a given micrograph.
< CTF Estimation | Create Particle Stack >