Project

General

Profile

OTR Volume » History » Version 19

Anke Mulder, 06/04/2010 11:29 AM

1 1 Pick-Wei Lau
h1. OTR Volume
2
3
The orthogonal tilt reconstruction method is an approach to generating single-class volumes with no missing cone for ab initio reconstruction of asymmetric particles (Leschziner & Nogales, 2005). The method involves collecting data at +45° and −45° tilts and only requires that particles adopt a relatively large number of orientations on the grid. One tilted data set is used for alignment and classification and the other set—which provides views orthogonal to those in the first—is used for reconstruction, resulting in the absence of a missing cone.
4 15 Anke Mulder
5
!http://emg.nysbc.org/attachments/258/Picture_47.png!
6 2 Pick-Wei Lau
7 17 Anke Mulder
h2. General Workflow:
8 2 Pick-Wei Lau
9 19 Anke Mulder
h3. 1. Requirements:
10 5 Pick-Wei Lau
11 4 Pick-Wei Lau
# Run either [[Auto Align Tilt Pairs]] or [[Align and Edit Tilt Pairs]]
12
# Create two stacks: 1) Consist of only your first exposure particles and 2) Consist of only your second exposure particles
13
# Perform an alignment or classification run of your second-exposure particle stack
14
15 19 Anke Mulder
h3. 2. Step by Step Guide:
16 5 Pick-Wei Lau
17 10 Pick-Wei Lau
There are two general methods to run OTR Volume, just like how one would run [[RCT Volume]] 
18 7 Pick-Wei Lau
19
# From class averages after running alignment or classification:
20 17 Anke Mulder
## By selecting a desired class average (using the "select" selection mode) and then clicking on the button "Create OTR Volume", the user will be taken to the "Run OTR Volume" launch page. 
21
## On this page, the user will provide the a brief description of the run, select the corresponding stack with respect to the stack on which the alignment or classification is performed and select the mask radius.
22
## The other options are set on defaults
23 12 Pick-Wei Lau
# From the menu tab under Ab Initio Reconstruction:
24 17 Anke Mulder
## By clicking on the OTR Volume link, the user will be taken to the "Run OTR Volume" launch page.
25
## In this case, since the desired class average is not defined, the user has to choose the alignment or classification run and define the the class average number to reconstruct the OTR volume.
26
## Once that is done, the rest of the options are exactly the same as launching OTR volume from class averages in Method 1
27 12 Pick-Wei Lau
28 19 Anke Mulder
h3. 3. Viewing OTR Volume Output Pages:
29 17 Anke Mulder
30 18 Anke Mulder
31
h2. Notes, Comments, and Suggestions:
32
33 16 Anke Mulder
______
34 14 Anke Mulder
35 16 Anke Mulder
[[Ab Initio Reconstruction|< Ab Initio Reconstruction]] | [[Refine Reconstruction|Refine Reconstruction >]]
36 1 Pick-Wei Lau
37 16 Anke Mulder
______