3 | 2 | Pick-Wei Lau | h2. *Introduction:* |
4 | |||
5 | 1 | Pick-Wei Lau | The orthogonal tilt reconstruction method is an approach to generating single-class volumes with no missing cone for ab initio reconstruction of asymmetric particles (Leschziner & Nogales, 2005). The method involves collecting data at +45° and −45° tilts and only requires that particles adopt a relatively large number of orientations on the grid. One tilted data set is used for alignment and classification and the other set—which provides views orthogonal to those in the first—is used for reconstruction, resulting in the absence of a missing cone. |
6 | 2 | Pick-Wei Lau | |
7 | h2. *OTR Processing in Appion:* |
||
8 | |||
9 | h3. Requirements: |
||
10 | 5 | Pick-Wei Lau | |
11 | 4 | Pick-Wei Lau | # Run either [[Auto Align Tilt Pairs]] or [[Align and Edit Tilt Pairs]] |
12 | # Create two stacks: 1) Consist of only your first exposure particles and 2) Consist of only your second exposure particles |
||
13 | # Perform an alignment or classification run of your second-exposure particle stack |
||
14 | |||
15 | h3. How to run OTR within Appion: |
||
16 | 5 | Pick-Wei Lau | |
17 | 6 | Pick-Wei Lau | There are two general ways to run OTR Volume, just like how one would run [[RCT Volume]] |
18 | 7 | Pick-Wei Lau | |
19 | # From class averages after running alignment or classification: |
||
20 | > By selecting a class average and then clicking on the button "Create OTR Volume", the user will be taken to the "Run OTR Volume" launch page. |
||