Bug #1245
closed
subtomomaker.py uses wrong full tomogram binning
Added by Anchi Cheng over 13 years ago.
Updated over 12 years ago.
Affected Version:
Appion/Leginon 2.1.0
Description
cause an out of range error on the center of the subtomogram trimming
- Target version set to Appion/Leginon 2.2.0
fixed in r15511 might need to go into branch 2.1 as it is a fatal bug if the script is used to create subtomogram
Left a cause to use the aligner bin in case I have not thought of something that causes full tomogram to have no binning. Will not close this bug until I have a chance to run full test of the tomography pipeline.
Anchi, do you think you will have a chance to run a full tomography test in the next few days?
- Status changed from Assigned to Closed
tested on 12mar26c/tomo/tiltseries2/full3/subtomo_pick24
Also available in: Atom