Focus sequence problem

Added by Matthias Brunner over 14 years ago. Updated about 11 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
-
Start date:
05/25/2010
Due date:
% Done:

0%

Estimated time:
Affected Version:
Appion/Leginon 2.0.1
Show in known bugs:
Yes
Workaround:

Give 2 different names for different sequences.


Description

If you have 2 steps in focus sequence at the same preset (i.e. repeat for better convergence), defocus measurement fails because defocus is not applied for the second stage.
Preset does not change for the second step.

Fix: Force always a preset change in focus sequence.