Bug #2302
open
  
    
    
  
Frealign refinejob form hp and lp are reversed
 
        
        Added by Anchi Cheng over 12 years ago.
        Updated over 12 years ago.
        
Affected Version:
Appion/Leginon 3.0.0
 
 
  
  
  
  Description
  
  selectPreparedRecon.php gives wrong RMAX1 and RMAX2 to frealign refinement and wrong help string.
	Low resolution limit imposes a high-pass filter (hp)
High resolution limit imposes a low-pass filter (lp)
   
 
 
  
  
    
    
    
    
       - Status changed from Assigned to In Code Review
 
       - Assignee changed from Anchi Cheng to Dmitry Lyumkis
 
    
    r17480 switch the object.
	testing:
	1. Show the frealign refinement selection form such as myamiweb/processing/selectPreparedRecon.php?expId=9668
2. The RMAX1 should give help string for high-pass filter.
3. When default parameters are set, RMAX1 should be 300 while RMAX2 should be smaller number
4. When the command is displayed hp=300 and lp=10 should be the default.
 
     
   
  
  
    
    
    
    
       - Status changed from In Code Review to In Test
 
       - Assignee changed from Dmitry Lyumkis to Anchi Cheng
 
    
    looks good, except that the default for "low-pass filter (lp)" should not say "2*nyquist"
 
     
   
  
  
    
    
    
    
       - Status changed from In Test to In Code Review
 
       - Assignee changed from Anchi Cheng to Dmitry Lyumkis
 
    
    nice review.  Switched in r17483
 
     
   
  
 
  
  
 
Also available in:  Atom
  PDF